Polarimetry
Measures rotation of polarized light by chiral substances.
Practise Analytical, Lab & Spectroscopy All Analytical, Lab & Spectroscopy topics
Measures rotation of polarized light by chiral substances.
Practise Analytical, Lab & Spectroscopy All Analytical, Lab & Spectroscopy topics
Polarimetry measures the rotation of plane-polarized light by optically active compounds, which contain chiral centres and therefore have non-superimposable mirror images. Plane-polarized light passes through a sample tube of known length, and the observed rotation angle is measured with an analyser. The specific rotation, [alpha], equals the observed rotation divided by the path length in decimetres and the concentration in g/mL, and it is characteristic of a compound at a given temperature and wavelength. The sign shows whether the compound is dextrorotatory (positive) or levorotatory (negative). Polarimetry is used to determine concentration and enantiomeric excess.
Key ideas: Specific rotation [alpha] = alpha_obs/(l x c), with l in dm and c in g/mL. Enantiomeric excess (percent ee) = (observed [alpha]/pure enantiomer [alpha]) x 100. Racemic mixtures give zero rotation. Sucrose has [alpha] of plus 66.5 degrees, and on hydrolysis to glucose and fructose it becomes negative (invert sugar), which is used to follow reaction kinetics.
Common mistakes and connections: Students expect that sign of rotation relates to R or S configuration, but it cannot be predicted from the label. Rotation depends on wavelength, temperature, solvent and concentration, so quote conditions. An observed rotation of zero does not prove the absence of chiral compounds, because a racemate or meso compound gives zero. Related to chirality, stereoisomers and enantiomers.
With specific rotation +66.5 for sucrose, observed rotation grows linearly with concentration, so measuring the angle gives the concentration. The interactive lesson shows this as a live animation or chart.
A sucrose solution rotates plane-polarized light to the right, so its concentration in syrup can be measured by polarimetry.
Measures rotation of polarized light by chiral substances.
Polarimetry is a advanced topic in Analytical, Lab & Spectroscopy. It builds on beginner and intermediate topics, so review those first if needed.
Study these earlier topics in Analytical, Lab & Spectroscopy first: Phosphorescence, Chemiluminescence, Atomic Emission Spectroscopy.
The next topics in Analytical, Lab & Spectroscopy are Refractive Index and Melting Point Determination.
Yes. The interactive lesson includes a self-check question on Polarimetry, and the Analytical, Lab & Spectroscopy quiz draws on every topic in this area.
Polarimetry is topic 76 of 99 in Analytical, Lab & Spectroscopy.